Fire Trainer Liner

Responses due30h leftJul 30, 2026, 2:00 PM EDT
Sub-tierDepartment of the Air Force
OfficeFa4809 4th Cons Sq Cc
PSC4240
PostedJul 15, 2026
DeadlineJul 30, 2026, 2:00 PM EDT
Place of performanceGoldsboro, NC, 27531
From the notice

SALIENT CHARACTERISTICS for Structural Trainer Liner DESCRIPTION: Replace liner inside the structural trainer REQUIREMENTS: The liner components units shall: 1. Designed to meet all referenced safety, thermal, and regulatory specifications, this specific material is engineered for extreme live-fire training evolutions. 2. Specifically formulated for Class A, B, C, D, Electrical, and F/K fires within a controlled burn cell which complies with NFPA 1402 and related standards. 3. Made of a cementitious high temp composite formula, which has a negative health impact when installed by certified installers. 4. Have Kevlar additives 5. Unique tongue and groove installation method 6. Stainless Steel mounting hardware 7. Have five (5) to ten (10) year warranty to replace 8. Able to withstand 150 psi nozzle forces 9. 1.5 inches thick requires no additional insulation behind its barrier 10. Heat transfer 10.4% (1000 degree / 140 degree in 10 minutes) 11. Complies with all NFPA suggested burn mat…